CHAPTER 5 Chapter System Startup/Shutdown and Power Control 
5.1 System Power on and Power off 
37 
 
C122-E175-01EN 
 
 Chapter System 
CHAPTER 5
Startup/Shutdown and Power Control 
This section describes the startup, shutdown and the power control in Cisco C880 server. 
5.1 
System Power on and Power off 
This section describes various procedures of power on and Power off for the system and explains the method 
of checking power supply. 
5.1.1  Various Methods for Powering On the System 
There are three methods for powering on the system, which are as follows.  
1.  Operation through the MMB Web-UI or MMB CLI.  
The system can be powered on through the MMB Web-UI or MMB CLI operation. 
2.  Scheduled operation (Automatic operation according to a set schedule) 
A system can be powered on by a scheduled operation (Automatic operation function). 
3.  Wake On LAN (WOL) 
The system can be power on with WOL. 
Notes 
You can enable or disable WOL of LAN ports on IOU per IOU by MMB Web-UI. Default value of WOL is 
‘disable’. If you use WOL of LAN port on IOU, set Onboard LAN Mode to ‘Enabled’ (WOL enable). 
If the power supply is stopped or IOU is pulled out, the setting of WOL is initialized. 
Restore the setting of WOL with Operating System. 
Enable or Disable WOL is set from both BIOS and the operating system. 
To enable WOL in Windows, following settings are required for each port of the device manager Check 
the [Wake On Magic Packet from the powered off state] checkbox in [Device Manager] 
– [Network 
Adaptor] 
– [INTEL ® 82576 Gigabit Dual Port Network Connection] – [Property] – [Power Management]. 
In case of setting in windows, “Intel PROSet” of the supplied driver must be installed. 
To enable WOL in BIOS, following setting is required for each port: 
Enable [Wake on LAN] in the menu [Device Manager]-[Network Device List]-[NIC Configuration] 
5.1.2  Types of Power off Method of System 
The three methods to power off the system are as follows.  
1.  Shutdown from the operating system (Recommended) 
Shutdown the operating system by using the operating system commands. When powering off the system, 
perform the shutdown from the operating system. For the operating system shutdown commands, refer to 
the manual of each operating system.  
2.  Powering off of the system using the [MMB Web-UI] window or the MMB CLI. 
The power can be turned off by the Web window operation of an external terminal, or the MMB CLI. 
3.  Powering off the system by a scheduled operation. 
The system can be powered off by a scheduled operation (Automatic operation function). 
Notes 
In the following cases, confirm the details according to ‘
’. If the error recurs, contact your 
sales representative or field engineer. 
Before contacting, confirm the model name and serial number shown on the label affixed on the main unit.  
Until the problem is solved, do not execute [Reset], [Force Power Off] for the system. 
When [Power Off], [Reset], or [Force Power Off] is executed for system, or when shutting down from the 
operating system, the MMB Web-
UI (Information area) status changes to “Error”.