Software Upgrade Procedure
Software Upgrade Procedure
General Important Information
We recommend that you use the latest version of Management Software when you upgrade a network
element (NE) from an older release. This is because an upgrade may imply either a change in the object
identifier (OID) or a change in feature attributes for features supported by the device, or both. Any
management software that Ericsson supplies would require support for the new OID and changed feature
attributes. Check the release note for the management software about supported NE versions.
element (NE) from an older release. This is because an upgrade may imply either a change in the object
identifier (OID) or a change in feature attributes for features supported by the device, or both. Any
management software that Ericsson supplies would require support for the new OID and changed feature
attributes. Check the release note for the management software about supported NE versions.
If you are using AXX 9820 CRAFT, you may require to reconnect to the device to re-synchronize the
changes after download.
changes after download.
History of changes in object ids for the ONS 15305:
•
R1.01.3.6.1.4.1.7546.1.4.1.1.1
•
R1.11.3.6.1.4.1.7546.1.4.1.1.2
•
R2.01.3.6.1.4.1.7546.1.4.1.1.3
Cisco Edge Craft (CEC) R.2.2 is the minimum required for operating this network release of
ONS 15305. Cisco ONS 15305 2.x includes CEC and network release.
ONS 15305. Cisco ONS 15305 2.x includes CEC and network release.
Caution
Do not insert the new Ethernet modules such as 2xGE + SMAP, 8xFE + SMAP, and 8xFE-SFP, before
the NE is upgraded to network release 2.x. The software package must be loaded on the Compact Flash
card. Both the main card and system controller must be upgraded before the modules are inserted, else
it will cause the device to continuously restart.
the NE is upgraded to network release 2.x. The software package must be loaded on the Compact Flash
card. Both the main card and system controller must be upgraded before the modules are inserted, else
it will cause the device to continuously restart.
Note
When upgrading from a device running release 1.x, download the system controller software
(45004-77BA_PM_ED16.bin) separately before you upgrade to R.2.1. When restarted, the network
release download (55004-01BA_PM_ED16.def) can be issued, which will be stored in the Compact
Flash card on the system controller.
(45004-77BA_PM_ED16.bin) separately before you upgrade to R.2.1. When restarted, the network
release download (55004-01BA_PM_ED16.def) can be issued, which will be stored in the Compact
Flash card on the system controller.
Note
Configuration backups (CDB) taken on devices running ONS 15305 R1.1.0 and older versions cannot
be restored on devices running ONS 15305 R1.1.1 and later releases. After ONS 15305 R1.1.1 (and later
releases) is online, a new configuration backup must be made that is forward compatible. After AXX
9200 EDGE R.1.1 ICS05 (and later) is online, a new configuration backup must be made that is forward
compatible.
be restored on devices running ONS 15305 R1.1.1 and later releases. After ONS 15305 R1.1.1 (and later
releases) is online, a new configuration backup must be made that is forward compatible. After AXX
9200 EDGE R.1.1 ICS05 (and later) is online, a new configuration backup must be made that is forward
compatible.
Note
When upgrading the ONS 15305 from R.1.x, it may be experienced that modules containing Ethernet
switches do not initialize (HotSwap Failure alarm). A resolution for this issue (too short GALNET reset)
is provided from R1.1.1. However, it is activated only on the next system restart. The workaround is an
individual module restart. Upgrade through a local management connection, even when the device is
available through other management connections.
switches do not initialize (HotSwap Failure alarm). A resolution for this issue (too short GALNET reset)
is provided from R1.1.1. However, it is activated only on the next system restart. The workaround is an
individual module restart. Upgrade through a local management connection, even when the device is
available through other management connections.