Chapter 2        Module Installation 
 
 
 
66 
 
locally or from the factory. The chassis data sheet lists the part number for a 6-foot 
DB9 Female to DB9 Male serial extension cable. The connectors are a serial 9-pin D-
shell (EIA 574/232). 
 
To Connect Chassis-to-Chassis ICIM IN and ICIM OUT Ports 
1  Connect the serial extension cable from the ICIM OUT of the chassis containing 
the ICIM to the ICIM IN connector of the second chassis. 
2  Connect a serial extension cable from the ICIM OUT of the second chassis to the 
ICIM IN of the third chassis. 
3  Continue this daisy-chain connection until all chassis are connected. 
4  Connect an ICIM OUT terminator, part number 4013014, to the ICIM OUT 
connector on the last chassis in the daisy-chain connection. The ICIM OUT 
terminator ships with the ICIM. 
Important: 
 
All chassis connected in the daisy-chain must be powered and have a fan tray 
installed. A chassis connected in the daisy-chain that is not powered or has no 
fan tray installed will cause faulty operation of the ICIM. 
 
All chassis connected in this daisy-chain must have a unique chassis ID number. 
 
If the ICIM OUT terminator that ships with the ICIM is not installed on the last 
chassis of a daisy-chain connection, faulty communication with the ICIM may 
occur.