Chapter 4 Front Panel Operation
102
78-4039426-01 Rev D
4 Set the Act for the selected PMT to either Pass, Drop, or Map depending on the
action desired.
A program can be set to one of three output modes, either Drop, Pass or Map.
A program can be set to one of three output modes, either Drop, Pass or Map.
LCD Setting
Description
Drop
Removes the service and its associated PMT reference
from the transport output.
from the transport output.
Pass
Permits the source content and PMT reference to
appear in the transport output with the same
references.
appear in the transport output with the same
references.
Map
Provides the flexibility to define all the outgoing PID
numbers for the PE, including those not currently on
transmission.
numbers for the PE, including those not currently on
transmission.
5 Use the RIGHT arrow key to move to the right and select PID to display the
detailed menu level.
6 Configure the input to output channel mapping. Video and PCR can be output
on the same PID or different PIDs. If output on the same PID, they will appear
identical to the input.
Note: If the parameters cannot be saved, the problem may be that the incorrect
Map Mode has been selected. Ensure that Svc ID & PID is selected when
remapping PIDs, otherwise a message such as “Bad configuration data” will be
displayed and you will need to change the parameters to obtain the correct
output.
identical to the input.
Note: If the parameters cannot be saved, the problem may be that the incorrect
Map Mode has been selected. Ensure that Svc ID & PID is selected when
remapping PIDs, otherwise a message such as “Bad configuration data” will be
displayed and you will need to change the parameters to obtain the correct
output.
7 Go to Setup: Outputs, TS Out: ASI, and set the Output Mode to Full DPM
Control. Also, if necessary set the Descramble Mode according to whether the
program is to be Scrambled or Descrambled for downstream
viewing/monitoring.
program is to be Scrambled or Descrambled for downstream
viewing/monitoring.
8 On the same menu, set the following parameters:
Parameter
Description
Map Mode
Svc ID & PID
Duplic Mode
Pkt Copy
Unref
Drop
PSI Options
Ctl By Table
PSI Rate
Any
Svc ID
Any
9 Set the table parameters as follows:
Parameter
Description
PAT
Regen
CAT
Regen