7 Select the Relay Mode that can be programmed to respond to an Alarm state,
Warning statue, or the state of one of the eight cue trigger pins. The response is
generated at the Cue Tone/Relay output on the rear panel of the receiver. The
following table shows what the possible field settings are and their relationship
to the receiver output:
generated at the Cue Tone/Relay output on the rear panel of the receiver. The
following table shows what the possible field settings are and their relationship
to the receiver output:
Relay Mode
Condition
Relay Contact
NC - C
C-NO
Alarm
Unit Power Off
Open
Close
Alarm State
Open
Close
No Alarm
Close
Open
Trigger
Active (selected in PNC) Close
Open
Inactive
Open
Close
8 If the Relay Mode was set to Trigger, select the cue trigger bit/pin that will
activate the relay in the Relay Trigger Bit drop-down menu (1 to 8).
9 Click Apply.