2 For each DPM Program Entry, it displays the input channel number (Chl #) and
channel name (Name), whether the PE is passed, dropped, or mapped (Action),
the output channel (Output Ch#), and the PMT PID (PMT PID).
Note: Any changes made to the DPM Program Entry Setup configuration
automatically changes the Output Mode to Full DPM Control in the MPEG over
IP Output page.
the output channel (Output Ch#), and the PMT PID (PMT PID).
Note: Any changes made to the DPM Program Entry Setup configuration
automatically changes the Output Mode to Full DPM Control in the MPEG over
IP Output page.
3 Select the program entry you want to edit.
4 The Action is automatically updated when you select the Output Mode in the
4 The Action is automatically updated when you select the Output Mode in the
ASI Output page. For more information, see Configuring the MPEGoIP Output
(on page 173). You can optionally select the DPM program action for the PE
(Pass, Map, or Drop) in the Action drop-down list.
Note: If the PE is mapped, it uses the last valid input. The output map (for
example, output channel PMT) does not change automatically if the input or
channel number is changed.
(on page 173). You can optionally select the DPM program action for the PE
(Pass, Map, or Drop) in the Action drop-down list.
Note: If the PE is mapped, it uses the last valid input. The output map (for
example, output channel PMT) does not change automatically if the input or
channel number is changed.
5 Click Edit. The DPM PE PID MAP window opens.
6 Enter the Output Channel Number you want to map to the input channel (Input
Channel #). This value is only used if the PE Action was set to Map. You can
enter a range from 1 to 65535.
enter a range from 1 to 65535.
7 Enter the Output PMT PID you want to map to the Input PMT PID.
8 In the PE PID MAP section, you can select an existing PID mapping entry you
8 In the PE PID MAP section, you can select an existing PID mapping entry you
want to modify or click Add Row to create a new entry.
9 The Input Stream indicates the input program stream category/service type. The
Input PID displays the input program PID (1 to 8190). It is only used if the PID
Action is set to Map.
Action is set to Map.
10 In the Action drop-down, select the DPM action for the PID associated with the
PE.
Action
Description
Drop
Removes the service and its associated PMT reference from the
transport output.
transport output.