Cisco Aironet Base Station: Correcting a Yellow
Flashing LED
Document ID: 5807
Contents
Introduction
 Prerequisites
      Requirements
      Components Used
      Conventions
 Problem
 Solution
 Related Information
Introduction
This document discusses a Base Station flashing yellow LED and explains how to fix the problem.
Prerequisites
Requirements
There are no specific requirements for this document.
Components Used
This document applies to all models of the Cisco Aironet 340 series Base Station, and applies to all software
versions.
The information in this document was created from the devices in a specific lab environment. All of the
devices used in this document started with a cleared (default) configuration. If your network is live, make sure
that you understand the potential impact of any command.
Conventions
Refer to Cisco Technical Tips Conventions for more information on document conventions.
Problem
After an initial power up of the Base Station, sometimes the middle LED continues to flash yellow. This is
after the Base Station has been configured through the Base Station Client Utility (BSCU). This can indicate
that the Base Station has not received the configuration across the wireless link from the client adapter.
Solution
Use this solution to solve the problem.