Cisco Cisco Web Security Appliance S690 Notas de publicación

Descargar
Página de 76
46
C I S C O   I R O N P O R T   A S Y N C O S   6 . 3 . 8   F O R   W E B   R E L E A S E   N O T E S
Fixed: logconfig CLI command gives a misleading error message when entering in invalid 
value
Previously, when you used the 
logconfig
 CLI command to change the Log Rollover Interval 
to a value greater than 12 days, such as 13 days (“13d”), it returned a misleading error 
message saying the value cannot exceed “1,000,000.” This no longer occurs. Now, the error 
message very clearly states what values are allowed and not allowed. The Log Rollover 
Interval still cannot exceed 12 days. [Defect ID: 47488] 
Fixed: FTP transfers fail when the FTP transfer type is included in the URL
Previously, FTP transfers failed when the FTP transfer type was included in the URL. This no 
longer occurs. [Defect ID: 40265] 
Fixed: Some web pages do not open after requesting a web page from a buggy web 
server in some cases
Previously, when a user opened a web page from a buggy web server using the Authorization 
header and then navigated to a different website using the same browser session, the other 
website did not open. This no longer occurs. [Defect ID: 45584] 
Fixed: End-user notification pages do not display correctly because they do not contain 
UTF-8 encoding information
Previously, end-user notification pages did not display correctly because they did not contain 
UTF-8 encoding information. Some non-7-bit ASCII characters did not display. This no longer 
occurs. [Defect ID: 32009] 
Fixed: webcache CLI command allows duplicate entries
Previously, the 
webcache
 CLI command allowed users to enter duplicate entries. This no 
longer occurs. [Defect ID: 34493] 
Fixed: Range requests use too much bandwidth in some cases
Previously, range requests used too much bandwidth when the request was served from the 
destination server instead of the web cache. This happened because the Web Proxy 
downloaded more bytes from the server than was specified in the range request. This no 
longer occurs. [Defect ID: 39944] 
Fixed: SNMP service is disabled after upgrading
Previously, after you upgraded to the latest version of AsyncOS, the SNMP service was 
disabled if it was enabled before upgrading. This no longer occurs. [Defect ID: 41927]
Fixed: Incorrect value shown for Bandwidth Used in reports
Previously, an incorrect large negative value was shown for the “Bandwidth Used” field in 
some reports. This no longer occurs. [Defect ID: 42431]