System Unit
System Unit
System Unit
System Unit
Dimensions
Dimensions
Dimensions
Dimensions (H x W x D)
(with bezel)
3.45" x 17.64" x 28.23" in (8.76 x 44.80 x 71.71 cm)
Weight
Weight
Weight
Weight
(approximate)
Maximum
Maximum
Maximum
Maximum
(all hard drives, power
supplies, and processors
installed)
45.0 lb (16.80 kg)
Minimum
Minimum
Minimum
Minimum
(one hard drive, power
supply, and processor
installed)
32.0 lb (11.94 kg)
Input Requirements
Input Requirements
Input Requirements
Input Requirements
(per power supply)
Rated Line Voltage
Rated Line Voltage
Rated Line Voltage
Rated Line Voltage
90 -- 132 VAC,
180 - 264 V
Rated Input Current
Rated Input Current
Rated Input Current
Rated Input Current
460 Watt
7.1 A (at 120 VAC)
3.5 A (at 240 VAC)
750 Watt
7.4 A (at 120 VAC)
3.6 A (at 240 VAC)
Rated Input Frequency
Rated Input Frequency
Rated Input Frequency
Rated Input Frequency
50 to 60 Hz
Rated Input Power
Rated Input Power
Rated Input Power
Rated Input Power
460 & 750 watt - 852 W
BTU Rating
BTU Rating
BTU Rating
BTU Rating
Maximum
Maximum
Maximum
Maximum
460 Watt
1773 BTU/hr (at 120
VAC)
1715 BTU/hr (at 240
VAC)
750 Watts
2892 BTU/hr (at 120
VAC)
2797 BTU/hr (at 240
VAC
Power Specifications
Power Specifications
Power Specifications
Power Specifications
To review typical system power ratings use the Power Advisor which is
available via the online tool located at URL: 
Click on the system of interest. Example: DL180 G6
Follow the instructions of the next screens.
Power Supply Output
Power Supply Output
Power Supply Output
Power Supply Output
(per power supply)
Rated Steady-State Power
Rated Steady-State Power
Rated Steady-State Power
Rated Steady-State Power 460 W (at 100 VAC)
750 W (at 100 VAC)
460 W (at 200 VAC)
750 W (at 200 VAC)
Maximum Peak Power
Maximum Peak Power
Maximum Peak Power
Maximum Peak Power
460 W (at 100 VAC)
750 W (at 100 VAC)
460 W (at 200 VAC)
750 W (at 200 VAC)
System Inlet Temperature
System Inlet Temperature
System Inlet Temperature
System Inlet Temperature Operating
Operating
Operating
Operating
10° to 35°C (50° to 95°F) at sea level with an
altitude derating of 1.0°C per every 305 m
(1.8°F per every 1000 ft) above sea level to a
maximum of 3050 m (10,000 ft), no direct
sustained sunlight. Maximum rate of change is
10°C/hr (18°F/hr). The upper limit may be
limited by the type and number of options
installed.
QuickSpecs
HP ProLiant DL180 Generation 6 (G6)
HP ProLiant DL180 Generation 6 (G6)
HP ProLiant DL180 Generation 6 (G6)
HP ProLiant DL180 Generation 6 (G6)
Technical Specifications
DA - 13248   North America — Version 35 — May 19, 2011
Page 56