Troubleshooting
CSM-S error messages may be received and reported in the system log (syslog). This section describes 
these messages.
Message Banners
When syslog messages are received, they are preceded by one of the following banners (where # is the 
slot number of the CSM-S module):
Error Message CSM_SLB-4-INVALIDID Module # invalid ID 
00:00:00: CSM_SLB-4-DUPLICATEID Module # duplicate ID
00:00:00: CSM_SLB-3-OUTOFMEM Module # memory error
00:00:00: CSM_SLB-4-REGEXMEM Module # regular expression memory error
00:00:00: CSM_SLB-4-ERRPARSING Module # configuration warning
00:00:00: CSM_SLB-4-PROBECONFIG Module # probe configuration error
00:00:00: CSM_SLB-4-ARPCONFIG Module # ARP configuration error
00:00:00: CSM_SLB-6-RSERVERSTATE Module # server state changed
00:00:00: CSM_SLB-6-GATEWAYSTATE Module # gateway state changed
00:00:00: CSM_SLB-3-UNEXPECTED Module # unexpected error
00:00:00: CSM_SLB-3-REDUNDANCY Module # FT error
00:00:00: CSM_SLB-4-REDUNDANCY_WARN Module # FT warning
00:00:00: CSM_SLB-6-REDUNDANCY_INFO Module %d FT info
00:00:00: CSM_SLB-3-ERROR Module # error
00:00:00: CSM_SLB-4-WARNING Module # warning
00:00:00: CSM_SLB-6-INFO Module # info
00:00:00: CSM_SLB-4-TOPOLOGY Module # warning
00:00:00: CSM_SLB-3-RELOAD Module # configuration reload failed
00:00:00: CSM_SLB-3-VERMISMATCH Module # image version mismatch
00:00:00: CSM_SLB-4-VERWILDCARD Received CSM-SLB module version wildcard on slot #
00:00:00: CSM_SLB-3-PORTCHANNEL Portchannel allocation failed for module #
00:00:00: CSM_SLB-3-IDB_ERROR Unknown error occurred while configuring IDB
Server and Gateway Health Monitoring
Error Message SLB-LCSC: No ARP response from gateway address A.B.C.D.
Explanation
The configured gateway A.B.C.D. did not respond to ARP requests.
Error Message SLB-LCSC: No ARP response from real server A.B.C.D.
Explanation
The configured real server A.B.C.D. did not respond to ARP requests.
Error Message SLB-LCSC: Health probe failed for server A.B.C.D on port P.