Supported Platforms and Number of Modules per Platform 
Table 3 shows the platform support and the maximum number of Cisco 4-Port Clear Channel T1/E1 HWICs 
supported on each platform. 
Table 3. 
Number of Cisco 4-Port Clear Channel T1/E1 HWICs Supported per Platform 
Cisco Integrated Services 
Router Platform 
Cisco 2821, 
2851  
Cisco 2911 
Cisco 2921, 
2951 
Cisco 3825, 
3845, 3925, 
3945 
Cisco 3925, 
3925E, 3945, 
3945E 
Cisco 3925E, 
3945E 
Number of 4-port Clear Channel 
T1/E1 HWICs Supported 
Software and Management Features 
Table 4 shows the software and management features for the Cisco 4-Port Clear Channel T1/E1 HWIC. 
Table 4. 
Software and Management Features of Cisco 4-Port Clear Channel T1/E1 HWIC 
Feature 
Description 
Diagnostic Loopback Support 
  E1 loopback modes  
  Controller local loopback 
  Interface local loopback 
  T1 loopback modes 
  Interface local loopback 
  Interface remote loopback 
  Controller local loopback 
  Controller remote loopback 
  CSU loopback modes for T1 CSU 
  Data terminal equipment (DTE) loopback 
  Network loopback 
  Payload loopback 
Alarm Detection 
  Yellow alarm: Receive/send from/to network 
  Blue alarm: Receive alarm indication signal (AIS) from network 
  Red alarm: Loss of network signal 
Relevant MIB Support 
  RFC1406-MIB 
  CISCO-ICSUDSU-MIB 
Remote Management 
  Supported by Cisco WAN Access Performance Management System (WAPMS) 
  Cisco CNS 2100 Series Intelligence Engine (IE2100) 
  CiscoWorks 
Signaling Debugging 
  ISDN Q.921 and Q.931 decode 
  All other previously existing applicable Cisco IOS Software debugs 
Hardware Specifications 
Table 5 shows the hardware specifications for the Cisco 4-Port Clear Channel T1/E1 HWIC.  
Table 5. 
Hardware Specifications for Cisco 4-Port Clear Channel T1/E1 HWIC 
Feature 
Description 
Dimensions (H x W x D) 
0.75 x 3.08 x 4.74 in. (1.91 x 7.82 x 12.04 cm)  
Weight 
0.20 lb (0.09kg) 
Operating Temperature 
32 to 104°F (0 to 40°C) 
14 to 131F (–10C to 55C when installed in the MWR-2941-DC) 
Nonoperating Temperature 
-40 to 158° F (–40 to 70°C) 
Relative Humidity 