Cisco Cisco UCS C3160 Rack Server Hoja De Datos
Cisco UCS C240 M3 High-Density Rack Server (Large Form Factor Hard Disk Drive Model)
SUPPLEMENTAL MATERIAL
73
RAID Details
The available RAID configurations are shown in this section.
(1) 1-CPU Configurations
Mezzanine cards are not supported for 1-CPU configurations, Therefore, choose one of the
following RAID controllers for single-CPU configurations:
following RAID controllers for single-CPU configurations:
■
One internal drive RAID controller from
(LSI MegaRAID SAS 9271-8i or
9271CV-8i)
■
One external drive RAID controller from
(LSI MegaRAID SAS 9285CV-8e or
9286CV-8e)
(2) 2-CPU Configurations
Select a mezzanine card RAID option from
or an internal RAID controller, an
external RAID controller, or one of each if desired from
. You may also select
an appropriate optional RAID configuration listed in
. Choose one of the
following:
■
One mezzanine internal drive RAID controller from
.
■
One internal drive RAID controller from
(LSI MegaRAID SAS 9271-8i or
9271CV-8i)
■
One external drive RAID controller from
(LSI MegaRAID SAS 9285CV-8e or
9286CV-8e)
■
One external drive RAID controller and one internal drive RAID controller from
.
■
One mezzanine internal drive RAID controller from
and one external
NOTE: In 1-CPU configurations, PCIe slot 3 is the default slot supported for an
internal drive RAID controller. PCIe slots 1 and 2 can be used for one external drive
RAID controller if an internal drive PCIe RAID controller is not installed or for PCIe
expansion cards. PCIe slots 4 and 5 are not supported for 1-CPU systems. You can
change the default card slot for a RAID controller to a different slot by going into the
BIOS and reconfiguring the option ROM (OPROM) settings.
internal drive RAID controller. PCIe slots 1 and 2 can be used for one external drive
RAID controller if an internal drive PCIe RAID controller is not installed or for PCIe
expansion cards. PCIe slots 4 and 5 are not supported for 1-CPU systems. You can
change the default card slot for a RAID controller to a different slot by going into the
BIOS and reconfiguring the option ROM (OPROM) settings.
NOTE: In 2-CPU configurations, PCIe slot 4 is the default slot supported for an
internal drive RAID controller. The remaining slots can be used for one external drive
RAID controller if an internal drive PCIe RAID controller is not installed or for PCIe
expansion cards. You can change the default card slot for a RAID controller to a
different slot by going into the BIOS and reconfiguring the option ROM (OPROM)
settings.
internal drive RAID controller. The remaining slots can be used for one external drive
RAID controller if an internal drive PCIe RAID controller is not installed or for PCIe
expansion cards. You can change the default card slot for a RAID controller to a
different slot by going into the BIOS and reconfiguring the option ROM (OPROM)
settings.