Cisco Cisco Nexus 7000 F1-Series 32-Port 1 and 10 Gigabit Ethernet Module Guía Para Resolver Problemas

Descargar
Página de 4
Nexus 7000 F1 Module ELAM Procedure
Document ID: 116646
Contributed by Andrew Gossett, Cisco TAC Engineer.
Oct 22, 2013
Contents
Introduction
Topology
Determine the Ingress Forwarding Engine
Configure the Trigger
Start the Capture
Interpret the Results
Additional Verification
Introduction
This document describes the steps used in order to perform an ELAM on a Cisco Nexus 7000 (N7K) F1
module, explains the most relevant outputs, and describes how to interpret the results.
Tip: Refer to the ELAM Overview document for an overview on ELAM.
Topology
In this example, a host on VLAN 10 (10.1.1.101 with MAC address 0050.56a1.1a01), port Eth3/18 sends an
Internet Control Message Protocol (ICMP) request to a host that is also on VLAN 10 (10.1.1.102 with MAC
address 0050.56a1.1aef), port Eth3/26. ELAM is used in order to capture this single frame from 10.1.1.101 to
10.1.1.102. It is important to remember that ELAM allows you to capture only a single frame.
In order to perform an ELAM on the N7K, you must first connect to the appropriate module (this requires the
network−admin privilege):
N7K# attach module 3
Attaching to module 3 ...
To exit type 'exit', to abort type '$.' 
module−3# 
Determine the Ingress Forwarding Engine