Boxed Processor Specifications
Dual-Core Intel
®
 Xeon
®
 Processor 7000 Series Datasheet
105
solution limitations by using a load path attached to the chassis pan. The hat spring on the under 
side of the baseboard provides the necessary compressive load for the thermal interface material. 
The baseboard is intended to be isolated such that the dynamic loads from the heatsink are 
transferred to the chassis pan via the heatsink screws and heatsink standoffs. This reduces the risk 
of package pullout and solder joint failures in a shock and vibe situation.
The assembly requires larger diameter holes to compensate for the CEK spring embosses. See 
 for processor mounting thorough holes. 
8.3
Thermal Specifications
This section describes the cooling requirements of the heatsink solution utilized by the boxed 
processor.
8.3.1
Boxed Processor Cooling Requirements
The boxed processor will be cooled by forcing ducted chassis fan airflow through the passive 
heatsink solution. Meeting the processor’s temperature specifications is a function of the thermal 
design of the entire system, and ultimately the responsibility of the system integrator. The 
processor temperature specification is found in 
 of this document. For the boxed 
processor passive heatsink to operate properly, chassis air movement devices are required. 
Necessary airflow and associated flow impedance is 29 cfm at 0.10” H
2
O.
In addition, the processor pitch should be 3.25 inches, or slightly more, when placed in side by side 
orientation. 
 illustrates the side by side orientation and pitch. Note that the heatsinks are 
interleaved to reduce air bypass.
It is also recommended that the ambient air temperature outside of the chassis be kept at or below 
35 
°
C. The air passing directly over the processor heatsink should not be preheated by other 
system components (such as another processor), and should be kept at or below 40 
°
C. Again, 
meeting the processor’s temperature specification is the responsibility of the system integrator.
8.3.2
Boxed Processor Contents
The boxed processor will include the following items:
Dual-Core Intel
®
Xeon
®
 Processor 7000 Series
Unattached passive heatsink with captive screws
Thermal interface material (pre-attached)
Warranty/installation manual with Intel Inside logo
The other items required with this thermal solution should be shipped with either the chassis or the 
mainboard. They include:
CEK spring (typically included with mainboard)
Chassis standoffs
System fans
§