Cisco Cisco Firepower Management Center 4000 Guía Del Desarrollador

Descargar
Página de 726
Version 5.3
Sourcefire 3D System eStreamer Integration Guide
468
Understanding Legacy Data Structures
Legacy Intrusion Data Structures
Appendix B
The 
Intrusion Event (IPv4) Record Fields
 table describes each intrusion event 
record data field.
Interface Egress UUID
Interface Egress UUID, continued
Interface Egress UUID, continued
Interface Egress UUID, continued
Security Zone Ingress UUID
Security Zone Ingress UUID, continued
Security Zone Ingress UUID, continued
Security Zone Ingress UUID, continued
Security Zone Egress UUID
Security Zone Egress UUID, continued
Security Zone Egress UUID, continued
Security Zone Egress UUID, continued
Intrusion Event (IPv4) Record Fields 
F
IELD
D
ATA
 T
YPE
D
ESCRIPTION
Device ID
unit32
Contains the identification number of the 
detecting managed device. You can obtain the 
managed device name by requesting Version 3 
or 4 metadata. See 
 on page 99 for more information.
Event ID
uint32
Event identification number.
Event Second
uint32
UNIX timestamp (seconds since 01/01/1970) of 
the event’s detection.
Event 
Microsecond
uint32
Microsecond (one millionth of a second) 
increment of the timestamp of the event’s 
detection.
Rule ID 
(Signature ID)
uint32
Rule identification number that corresponds with 
the event.
Generator ID
uint32
Identification number of the Sourcefire 3D 
System preprocessor that generated the event.