Cisco Cisco MDS 9000 NX-OS Software Release 4.1 Notas de publicación
S e n d d o c u m e n t a t i o n c o m m e n t s t o m d s f e e d b a c k - d o c . c o m .
40
Cisco MDS 9000 Family Release Notes for Cisco MDS NX-OS Release 4.1(3)
OL-17675-03
Limitations and Restrictions
•
DS-C9216i-K9, Cisco MDS 9216i Multilayer Fabric Switch
•
DS-X9016, Cisco MDS 9000 2-Gbps16-Port Fibre Channel Switching Module
•
DS-X9032, Cisco MDS 9000 2-Gbps 32-Port Fibre Channel Switching Module
•
DS-X9032-14K9, Cisco MDS 9000 14/2-Port Multiprotocol Services Module (MPS-14/2)
For configuration information, refer to the “Configuring Trunking” section in the
Reserve VSAN Range and Isolated VSAN Range Guidelines
On an NPV switch with a trunking configuration on any interface, or on a regular switch where the
feature fport_channel_trunk command has been issued to enable the F PortChannel feature, follow
these configuration guidelines for reserved VSANs and the isolated VSAN:
feature fport_channel_trunk command has been issued to enable the F PortChannel feature, follow
these configuration guidelines for reserved VSANs and the isolated VSAN:
•
If trunk mode is on for any of the interfaces or NP PortChannel is up, the reserved VSANs are 3040
to 4078, and they are not available for user configuration.
to 4078, and they are not available for user configuration.
•
The Exchange Virtual Fabric Identifier (evfp) isolated VSAN is 4079, and it is not available for user
configuration.
configuration.
The following VSAN IDs are assigned in the Fibre Channel Framing and Signaling (FC-FS) interface
standard:
standard:
Compatibility of Fabric Manager and Data Mobility Manager
Cisco Fabric Manager in any MDS NX-OS 4.1(x) release does not support Data Mobility Manager
(DMM) in any SAN-OS 3.3(x) release or in any 3.2(x) release. To use the Cisco Fabric Manager GUI
for DMM, both Fabric Manager and DMM must be running NX-OS or SAN-OS software from the same
release series.
(DMM) in any SAN-OS 3.3(x) release or in any 3.2(x) release. To use the Cisco Fabric Manager GUI
for DMM, both Fabric Manager and DMM must be running NX-OS or SAN-OS software from the same
release series.
PPRC Not Supported with FCIP Write Acceleration
IBM Peer to Peer Remote Copy (PPRC) is not supported with FCIP Write Acceleration.
VF_ID Value
Value Description
00h
Do not use as a Virtual Fabric Identifier.
001h ... EFFh
Available as a Virtual Fabric Identifier.
F00h ... FEEh
Reserved.
FEFh
Control VF-ID (see Fibre Channel Link Services
(FC-LS) and Fibre Channel Switch Fabric
Generation 4 (FC-SW-4) standards).
(FC-LS) and Fibre Channel Switch Fabric
Generation 4 (FC-SW-4) standards).
FF0h ... FFEh
Vendor specific.
FFFh
Do not use as a Virtual Fabric Identifier.
FEFh = 4079