Caveats
•
CSCsx32050
Symptom: If you use Fabric Manager to upgrade a switch from NX-OS Release 4.1(3a) to a higher
release, Fabric Manager reports the status of a disruptive upgrade as Failure:none. If this situation
occurs, you can log into the switch and verify if the upgrade actually did succeed. Enter the show
version command to see if the switch reloaded and the new software version is running. If you
perform the upgrade from the CLI, this situation does not occur.
release, Fabric Manager reports the status of a disruptive upgrade as Failure:none. If this situation
occurs, you can log into the switch and verify if the upgrade actually did succeed. Enter the show
version command to see if the switch reloaded and the new software version is running. If you
perform the upgrade from the CLI, this situation does not occur.
Workaround: None.
•
CSCsx39418
Symptom: When you enter the show dmm tech-support command with the file option on the SSM
module, you might receive corrupted information, such as the following:
module, you might receive corrupted information, such as the following:
Switch# show dmm srvr-vt-login
======================================================================================
=========================================
Data Mobility Manager Server VT Login Information
======================================================================================
=========================================
Id Job Id VSAN Srvr pWWN Srvr FCID VT pWWN VT
FCID State (FC Redirect/Login)
======================================================================================
=========================================
1 1232653496 601 10:00:00:00:c9:3a:be:b0 0x7f0000 20:15:00:0b:fd:95:1f:84
0x7f0003 (READY/FCP_UP)
2 1232653496 601 10:00:00:00:c9:3a:be:b0 0x7f0000 20:17:00:0b:fd:95:1f:84
0x7f0002 (READY/FCP_UP)
Number of Logins :2
show dmm job job-id -5130593620553891840 details
===========================================================================
Data Mobility Manager Job Details
===========================================================================
Job Identifier : -5130593620553891840
Job Name : admin_2009/01/22-11:44
Job Type : SERVER
Job Rate : Default, no rate limiting
Job Mode : ONLINE
Job Method : METHOD-1
Job DPP : 1
Peer SSM IP : 10.10.2.7
Peer SSM IP : 0.0.0.0
Peer SSM IP : 0.0.0.0
Peer SSM IP : 0.0.0.0
[...]
Workaround: None.
•
CSCsx59908
Symptom: If a VSAN is removed from a FCIP TE port, traffic on that FCIP TE port in all other
VSANs will be disrupted. A VSAN can be removed in the following ways:
VSANs will be disrupted. A VSAN can be removed in the following ways:
–
The VSAN becomes isolated because of a domain overlap or a zone set merge conflict in the
VSAN.
VSAN.
–
There is a fabric binding failure.
–
A reconfigure fabric (RCF) frames occurs.
–
A VSAN is deleted on the switch.
–
A VSAN is removed from the allowed VSAN list on the port.
–
There is a trunk mode configuration change on the port.