  Caveats
Workaround: Use CFS regions if a large number (greater than 512) of application flows need to be 
configured. CFS regions segment the FCR peer topology into manageable proportions. 
CSCtr50223
Symptom: On the MDS 9513 switch, when an MSM-18/4 module boots up, it sends a request to the 
supervisor module to mount the modflash on the MSM-18/4 module. If there is a timeout or error in 
response, the following syslog message displays: 
2011 Jul 14 01:18:13 sw-dc5-br2-12 %LC_MNT_MGR-SLOT3-2-LC_MNT_MGR_ERROR: SUP mount 
failed. MTS receive timedout
2011 Jul 14 01:19:06 sw-dc5-br2-12 %PROC_MGR-SLOT3-2-ERR_MSG: ERROR: PID 1144 
(lc_mnt_mgr) exited abnormally, exit status (0xa)
2011 Jul 14 01:19:06 sw-dc5-br2-12 %MODULE-2-MOD_MINORSWFAIL: Module 3 (serial: 
JAE1141ZB43) reported a failure in service lc_mnt_mgr
This issue might be seen when the supervisor module is unusually busy and cannot process the 
mount request from the MSM-18/4 module, or the actual mount command on the supervisor takes a 
long time.
Workaround: Reload the MSM-18/4 module in the same slot/module where the modflash mount 
failed. A request will be sent to the supervisor to mount the modflash. 
CSCty82821
Symptom: After creating an SME cluster, adding disks to a disk group, changing some disk states, 
and starting master key rekey, the key creation date is invalid.
Workaround: None.
CSCua61011
Symptom: After creating an SME cluster in advanced mode, adding 500 disks to the disk group, 
exporting the keys, and importing the keys again, there is no scroll option in the import manage key 
window. 
Workaround: None.
CSCud49969
Symptom: If you enter the isapi health-check command after attaching the Cisco MDS 9000 
18/4-Port Multiservice Module (MSM-18/4), the following error appears:
Memory Status: ERROR
Conditions: This symptom might be seen after attaching the MSM-18/4 module and entering the 
isapi health-check command. The output shows “Memory Status: ERROR.”
Workaround: None.
CSCud72991
Symptom: A port drops all packets originating from the supervisor module. The packets are 
dropped as TIMEOUT drops. The port is up and has all of its allotted Tx B2B credits, but the input 
and output rate is 0 frames per second.
Workaround: Enter the shut command followed by the no shut command on the port to recover it.
CSCtz19169
Symptom: After the primary KMC fails over to the secondary, KMC performance suffers. The 
system attempts to reacquire connectivity to the primary KMC for each operation, and the system 
waits for that attempt to time out before using the secondary KMC. Waiting for the timeout creates 
a significant delay for failed over operations, particularly when scaled.
This symptom occurs when the primary KMC fails (because of loss of connectivity).