Cisco Cisco Aironet 1522 Lightweight Outdoor Mesh Access Point Hoja De Datos

Descargar
Página de 10
 
 
Ordering Guide 
© 2010 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public Information. 
Page 3 of 10 
In addition to the contents just listed, certain models include the following. The 1522AG, 1522PC, 1524SB, and 
1524PS include: 
 
Liquid tight adaptors (3) for sealing cable ingresses 
The 1522HZ include: 
 
Couplers (2) for connecting conduit pipes 
The access points are designed to withstand power surges on the AC power cord up to 4 kV as per EN61000-4-5 
Level 4; lightning arrestors are not required. 
Power 
The following models can be powered by 90-480 VAC or 48 VDC Power over Ethernet: 
 
1522AG 
 
1524SB 
 
1524PS 
The 1522HZ is powered by 90 VAC to 240 VAC. 
The following model is powered by 90 VAC to 240 VAC: 
 
1522PC 
The 1522PC can also be powered by Power over Ethernet (PoE) for lab usage. However, if a cable modem is 
installed, PoE will not power the cable modem. 
All models can alternatively be powered by 12 VDC using the supplied terminal block. 
AC Power 
The 1522AG, 1524SB, and 1524PS, and 1522PC access points have a 3-pin, threaded AC power connector. Table 
3 lists the power cord options available when you use AC power. 
Table 3. 
AC Power Cord Options 
SKU
 
Description
 
AIR-CORD-R3P-40NA 
 
Power cord, 40 ft, North American Plug
 
AIR-CORD-R3P-40UE
 
Power cord, 40 ft, European Harmonized, Unterminated
 
AIR-PWR-ST-LT-R3P
 
Power cord, 4 ft, Street Light Tap
 
1522HZ require discrete wired connection to internal terminal block. 
Note that the 1520 Series and 1500 Series AC power connectors are not compatible. You will need to use one of the 
power cables listed in Table 3 when using an access point in the 1520 Series. 
The AIR-CORD-R3P-40UE connects to the access point on one end, and is not terminated on the other end. You will 
need to source a plug appropriate for your installation. 
When AC power is not used (for example, when you use PoE or 12 VDC to power the access point), you should 
cover the unused connector. A cover is available from Remke (see 
http://www.remke.com
 for part number 75-0086).