  Powering the Access Point
Connecting an AC Power Cable to the Access Point 
When powering the access point with AC power other than the streetlight power tap adapter, you must 
ensure that the following conditions are observed: 
1.
AC power can be conveniently removed from the unit. The power should not be removed by 
disconnecting the AC power connector on the unit.
Warning
A readily accessible two-poled disconnect device must be incorporated in the fixed wiring. 
Statement 1022
Caution
Before connecting or disconnecting a power cord, you must remove AC power from the power cord using 
a suitable service disconnect.
2.
You must protect any AC power plugs and AC receptacles from water and other outdoor elements. 
You can use a UL-listed waterproofing enclosure suitable for covering the AC receptacle and AC 
power plug that supplies power to the unit as described in Article 406 of the NEC.
3.
When you install the access point outdoors or in a wet or damp location, the AC branch circuit that 
powers the access point should have ground fault protection (GFCI), as required by Article 210 of 
the National Electrical Code (NEC).
Note
For additional important safety instructions for AC power cords, refer to the AC Power Cords for Cisco 
Aironet 1520 Series Outdoor Mesh Access Points 
document that shipped with your AC power cords.
The access point supports this Cisco AC power cable:
40 ft (12.2 m) AC power cable (AIR-CORD-R3P-40NA=) 
To connect an AC power cable to the access point, perform these steps:
Step 1
Prior to applying AC power, ensure the access point is grounded (see 
).
Step 2
Turn off power to the AC power source at the designated circuits.
Warning
This unit might have more than one power supply connection. All connections must be removed to 
de-energize the unit. 
Statement 1028
Caution
When connecting the access point AC power connector, always connect the access point end of the cable 
first. When removing the AC power connector, always disconnect the access point end of the cable last
Note
If your access point contains a backup battery pack, you must press the reset button for 10 
seconds or more (see the
 
).