Cisco Cisco Firepower Management Center 4000 Notas de publicación

Descargar
Página de 33
Version 5.3
Sourcefire 3D System Release Notes
17
Updating Your Appliances
detailed instructions, see the Sourcefire Software for X-Series Installation and 
Configuration Guide.
Order of Installation
You must update your Defense Centers before you can update the devices they 
manage.
Installing the Update on Paired Defense Centers
When you begin to update one Defense Center in a high availability pair, the other 
Defense Center in the pair becomes the primary, if it is not already. In addition, 
the paired Defense Centers stop sharing configuration information; paired 
Defense Centers do not receive software updates as part of the regular 
synchronization process.
To ensure continuity of operations, do not update paired Defense Centers at the 
same time. First, complete the update procedure for the secondary Defense 
Center, then update the primary Defense Center.
Installing the Update on Clustered Devices
When you install an update on clustered devices, the system performs the 
update on the devices one at a time. When the update starts, the system first 
applies it to the secondary device, which goes into maintenance mode until any 
necessary processes restart and the device is processing traffic again. The 
system then applies the update to the primary device, which follows the same 
process.
Installing the Update on Stacked Devices
When you install an update on stacked devices, the system performs the updates 
simultaneously. Each device resumes normal operation when the update 
completes. Note that:
If the primary device completes the update before all of the secondary 
devices, the stack operates in a limited, mixed-version state until all devices 
have completed the update. 
If the primary device completes the update after all of the secondary 
devices, the stack resumes normal operation when the update completes 
on the primary device.
X-Series Devices
You cannot update X-Series appliances running Version 4.10.x to Version 5.3. 
Instead, you must uninstall the previous version and then install Version 5.3. For 
detailed instructions, see the Sourcefire Software for X-Series Installation and 
Configuration Guide.