Cisco Cisco Email Security Appliance C160 Referencia técnica
![Cisco](https://files.manualsbrain.com/attachments/7380d0050044647c30f5c24bbbf5d0c0b6d9bb84/common/fit/150/50/faa183d287233c52228cfea3dbc2a127fe780f60564fcb0955d9c3d1cd23/brand_logo.png)
485
Cisco IronPort AsyncOS 7.6 CLI Reference Guide
Chapter
- THROTTLING - Limit unique hosts tracked for rejected connection
reporting.
- TLD - Add customer specific domains for reporting rollup.
- STORAGE - How long centralized reporting data will be stored on the
C-series before being overwritten.
- LEGACY - Configure legacy mailflow report.
[]> storage
While in centralized mode the C-series will store reporting data for
the M-series to collect. If the M-series does not collect that data
then eventually the C-series will begin to overwrite the oldest data
with new data.
A maximum of 24 hours of reporting data will be stored.
How many hours of reporting data should be stored before data loss?
[24]> 48
SenderBase timeout used by the web interface: 5 seconds
Sender Reputation Multiplier: 3
The current level of reporting data recording is: unlimited
No custom second level domains are defined.
Legacy mailflow report: Disabled
Table 3-161
reportingconfig
- Configure storage limit for centralized
reporting data