Cisco Cisco Email Security Appliance C650 Notas de publicación
2
Release Notes for Hot Patch 2 for Cisco IronPort AsyncOS 7.5.2 for Email
Resolved Issues
Resolved Issues
The following issues are resolved in this release:
Table 1
Resolved Issues in this release of AsyncOS for Email
Defect ID
Description
87246
Fixed: SNMP Trap Not Generated When Hard Drive Disk is Pulled
Fixed an issue where the Email Security appliance did not generate an SMTP trap for
the removal of a hard drive disk.
the removal of a hard drive disk.
78982
Fixed: perCentDiskIOUtilization SNMP Query Reports No Such Object
Fixed an issue where the perCentDiskIOUtilization SMNP query incorrectly reported
“No Such Object available on this agent at this OID” instead of the proper disk IO
utilization value.
“No Such Object available on this agent at this OID” instead of the proper disk IO
utilization value.
69125
Fixed: resourceConservationMode SNMP Trap Missing from snmpconfig
Fixed an issue where the resourceConservationMode SNMP trap did not appear when
when you ran the
when you ran the
snmpconfig
command in the CLI.
79813
Fixed: powerSupplyStatus SNMP Trap Displaying Incorrect Information
Fixed an issue where removing one of the power supplies from the Email Security
appliance resulted in the powerSupplyStatus SNMP trap reporting
appliance resulted in the powerSupplyStatus SNMP trap reporting
NoAC
for both
power supplies, including the healthy one.
68126
Fixed: Ambient Temperature Sensor Failure Causes Appliance to Send High
Temperature SNMP Trap
Temperature SNMP Trap
Previously, the Email Security appliance’s SNMP code could not distinguish the
difference between a “no reading” status and a “high temperature” status for the
temperature sensors. This resulted in the appliance sending a “high temperature”
SNMP trap continuously if the appliance’s ambient temperature sensor failed or is out
of threshold ranges. This issue has been resolved.
difference between a “no reading” status and a “high temperature” status for the
temperature sensors. This resulted in the appliance sending a “high temperature”
SNMP trap continuously if the appliance’s ambient temperature sensor failed or is out
of threshold ranges. This issue has been resolved.
55755
Fixed: Appliance Doesn’t Send memoryUtilizationExceeded Trap to Target
Machine
Machine
Fixed an issue where the Email Security appliance did not send a
memoryUtilizationExceeded trap to a target machine when the appliance’s memory
utilization threshold was exceeded.
memoryUtilizationExceeded trap to a target machine when the appliance’s memory
utilization threshold was exceeded.