Using the System Setup Wizard
Note
Because the
systemsetup
command only configures one listener for both inbound and outbound mail for
C10/100 customers, all outgoing mail will be calculated in the Mail Flow Monitor feature (which is
normally used for inbound messages). See
normally used for inbound messages). See
Enable Anti-Spam
Your appliance ships with a 30-day evaluation key for the Anti-Spam software. During this portion of
the
the
systemsetup
command, you can choose to accept the license agreements and enable Anti-Spam
globally on the appliance.
Anti-Spam scanning will then be enabled on the incoming mail policy.
Note
If you do not accept the license agreement, Anti-Spam is not enabled on the appliance.
See
for all of the Anti-Spam configuration options available on the appliance.
Maximum Number Of Connections From A Single IP: 50
Maximum Number Of Messages Per Connection: 100
Maximum Number Of Recipients Per Message: 100
Maximum Number Of Recipients Per Hour: 450
Maximum Recipients Per Hour SMTP Response:
452 Too many recipients received this hour
Use SenderBase for Flow Control: Yes
Spam Detection Enabled: Yes
Virus Detection Enabled: Yes
Allow TLS Connections: No
Would you like to change the default host access policy? [N]>
Listener MailInterface created.
Defaults have been set for a Public listener.
Use the listenerconfig->EDIT command to customize the listener.
*****