Cisco Cisco Email Security Appliance X1070 Guía Del Usuario
3-30
Cisco AsyncOS 8.0.1 for Email User Guide
Chapter 3 Setup and Installation
Using the System Setup Wizard
Note
Because the
systemsetup
command only configures one listener for both inbound and outbound mail for
C10/100 customers, all outgoing mail will be calculated in the Mail Flow Monitor feature (which is
normally used for inbound messages). See
normally used for inbound messages). See
Do you want to enable rate limiting for this listener? (Rate limiting defines the
maximum number of recipients per hour you are willing to receive from a remote domain.)
[Y]> y
Enter the maximum number of recipients per hour to accept from a remote domain.
[]> 450
Default Policy Parameters
==========================
Maximum Message Size: 10M
Maximum Number Of Connections From A Single IP: 50
Maximum Number Of Messages Per Connection: 100
Maximum Number Of Recipients Per Message: 100
Maximum Number Of Recipients Per Hour: 450
Maximum Recipients Per Hour SMTP Response:
452 Too many recipients received this hour
Use SenderBase for Flow Control: Yes
Spam Detection Enabled: Yes
Virus Detection Enabled: Yes
Allow TLS Connections: No
Would you like to change the default host access policy? [N]>
Listener MailInterface created.
Defaults have been set for a Public listener.
Use the listenerconfig->EDIT command to customize the listener.
*****