C10/100/150/160 Listener Example
Note
The following example of creating a listener applies to C150/160 customers only.
In this example portion of the
systemsetup
command, a listener named MailInterface is configured to
run on the MailNet IP interface. Then, it is configured to accept all email for the domain
example.com
.
An initial SMTP route to the mail exchange
exchange.example.com
is configured. Then, the same
listener is configured to relay all email for all hosts within the domain
example.com
. (Note the dot at the
beginning of the entry:
.example.com
)
Rate limiting is enabled, and the maximum value of 450 recipients per hour from a single host is
specified for the public listener.
specified for the public listener.
[]> .example.com
Do you want to enable rate limiting for this listener? (Rate limiting defines the
maximum number of recipients per hour you are willing to receive from a remote domain.)
[N]> n
Default Policy Parameters
==========================
Maximum Message Size: 100M
Maximum Number Of Connections From A Single IP: 600
Maximum Number Of Messages Per Connection: 10,000
Maximum Number Of Recipients Per Message: 100,000
Maximum Number Of Recipients Per Hour: Disabled
Use SenderBase for Flow Control: No
Virus Detection Enabled: Yes
Allow TLS Connections: No
Would you like to change the default host access policy? [N]> n
Listener OutboundMAil created.
Defaults have been set for a Private listener.
Use the listenerconfig->EDIT command to customize the listener.
*****