Cisco Cisco Aironet 1200 Access Point Notas de publicación

Descargar
Página de 15
8
Reboot of Workgroup Bridges Required When Allowing More Than 20
OL-3159-01
Caveats
To use a terminal emulator to open the 1200 series access point’s command-line interface (CLI), use 
these settings for the terminal emulator connection: 
9600 baud
8 data bits
No parity
1 stop bit
No flow control or Xon/Xoff
Reboot of Workgroup Bridges Required When Allowing More Than 20
With firmware version 11.56, you can select no for the Classify Workgroup Bridges as Network 
Infrastructure
 setting on the AP/Root Radio Advanced page to allow up to 50 workgroup bridges to 
associate to the access point. When you select no for this setting, you must reboot workgroup bridges 
associated to the access point.
Cisco Discovery Protocol Re-Enabled for Individual Interfaces on Reboot 
The Cisco Discovery Protocol (CDP) feature is enabled by default, and CDP is enabled for each of the 
access point’s CDP-relevant interfaces by default. However, if you disable CDP for one of the individual 
interfaces, the access point re-enables CDP for that interface when it reboots. If you disable CDP 
completely, the access point does not re-enable CDP on reboot.
Caveats
This section lists resolved and open software issues in firmware version 11.56.
Getting Bug Information on Cisco.com
If you are a registered Cisco user, you can use the Cisco TAC Software Bug Toolkit, which consists of 
three tools (Bug Navigator, Bug Watcher, and Search by Bug ID Number) that help you identify existing 
bugs (or caveats) in Cisco software products. 
Access the TAC Software Bug Toolkit at 
.
Open Caveats
The following caveats have not been resolved for firmware version 11.56:
CSCdy03381—One access point radio sometimes fails to restart after a warm reset. Workaround: 
Perform a cold reboot of the access point if one of the radios does not restart.
CSCdy10787—The access point aborts any configuration containing an unknown MIB variable. 
When an access point receives a configuration from another access point that is running a newer 
firmware version than the receiving access point, the receiving access point aborts the configuration 
if it encounters a MIB variable that it does not recognize. Workaround: Upgrade access points to the 
same firmware version before distributing configurations.