Low Power Condition
The access point can be powered from the 48-VDC power module or from an in-line power source. 
The access point supports the IEEE 802.3af power standard for in-line power sources. For operation, 
the access point (powered device) requires 10 watts of input power. 
Note
When the access point is used in a PoE configuration, the power drawn from the power 
sourcing equipment (PSE), such as a switch or power injector, is higher by an amount 
dependent on the length of the interconnecting cable.
The power module (AIR-PWR-1000=) and the Cisco Aironet power injector (AIR-PWRINJ-1000af=) 
are capable of supplying the required operating power, but some inline power sources are not capable 
of supplying sufficient power. Also, some high-power inline power sources might not be able to 
provide sufficient power to all ports at the same time.
Note
An 802.3af compliant switch (Cisco or non-Cisco) is capable of supplying sufficient power for 
full operation.
Green
Off
Blinking 
yellow
On or off
Normal operation, 2.4-Ghz radio activity.
If one or both radio LEDs remain off, there may 
be a problem with the wireless network. Check 
the controller configuration for the access point.
Power
LED
Alarm
LED
2.4 Ghz
LED
5 GHz
LED
Description
All LEDs blink on and off simultaneously.
Access point is association to the controller and 
is downloading new operating system code.
Off
Blinking 
red
Off
Off
Duplicate access point IP address detected.
Contact your network administrator.
All LEDs are off.
No power or a low power condition.
Blinking 
green
Off
Off
Off
Site survey mode on the AP-1010 and AP-1020 
models. Disconnected from the root access point 
on the AP-1030 model.
Table 2