Cisco Cisco Aironet 3500p Access Point Guía De Instalación

Descargar
Página de 16
 
9
Cisco Aironet Six-Element Dual-Band MIMO Patch Array Antenna (AIR-ANT25137NP-R)
OL-23461-01
  Installing the Antenna
Installing the Antenna
You can install the antenna on any flat surface or on a pole with a maximum 
diameter of 3 inches (7.62 cm). The antenna and mounting bracket are assembled 
and connected together when shipped. When mounting the antenna you only need 
to connect the bracket to the mounting surface and adjust the antenna orientation. 
Tools and Equipment Required
You will need these tools to loosen and tighten the adjustment bolts on the 
bracket:
A 10-mm wrench or socket
To mount the antenna on a wall or ceiling, you will need these supplies:
Four mounting screws or bolts and wall anchors
Note
The fasteners and mounting surface should be capable of maintaining a 
minimum pullout force of 150 pounds (68 kg) to support the weight of the 
antenna and bracket plus the potential wind loading on the antenna.
To mount the antenna on a pole or mast, you will need these supplies:
Two U-bolts 
Note
Cisco recommends using a guillotine-style U-bolt or a U-bolt with a 
notched, toothed backing plate to ensure proper support and permanent 
positioning.
Note
The pole or mast must be rigid enough to hold the weight of the antenna 
plus the associated forces produced by wind loads.  In addition, the pole 
or mast must be structurally strong enough to withstand the clamping 
force of the U-bolts.
You may need the following tools and equipment, which are not provided:
A drill and drill bit