Cisco Cisco Aironet 3500p Access Point Hoja De Datos

Descargar
Página de 29
Wireless CleanAir Deployment Guide
Smart Business Architecture
Step 9:
 Select Add Template.
Step 10:
 Create a template name as follows:
1. Check the Event Driven RRM Enable check box.
2. Change the Sensitivity Threshold to Medium.
3. Click Save.
Step 11:
 Select Apply to Controllers….
Step 12:
 Leave Apply to controllers selected directly and check All Controllers
and click OK.
Figure 43.
Apply to All Controllers
Troubleshooting with CleanAir
The real power of CleanAir is that a network administrator can be on one continent 
while the Wi-Fi spectrum in another office on the other side of the planet can be  
analyzed directly. The 3500 access points can be put in SE-Connect mode and 
used as a virtual remote interface for the knowledgeable engineer no matter 
where this valuable human resource is located. By changing the role of your 
CleanAir access point and connecting the Spectrum Expert 4.0 software, the 
Wi-Fi network administrator can now view the environment directly. There is no 
longer a need to fly expensive personnel onsite to troubleshoot physical layer 
issues that are unknown and challenging and, too often, intermittent issues.
Accessing Remote CleanAir for Spectrum Connect
When the call for assistance arrives, it is almost certainly to be in a location that 
does not have the knowledgeable human resources to troubleshoot, identify, 
and fix the issue. Wi-Fi radios are designed to send and receive Wi-Fi signals, 
but they do not have the capability to identify non-Wi-Fi radio interferers such as  
microwave ovens, DECT phones, analog wireless cameras, or even radio jammers.  
The specialized radios in the CleanAir radio can identify and, with triangulation, 
can locate where these devices are located.  
When the call comes in, it is always important to identify as many facts about 
the issue to make informed decisions. The information can be the location of the 
problem (for example, “the street side of the building does not have connectivity”)  
and time of day (for example, “the issue is pronounced at lunch time”). With as 
much information from the end user as possible, it is now time to look at the 
radio environment because the system shows that clients are connecting and 
WCS indicates AirQuality has dropped…
Configure Spectrum Connect
The CleanAir-capable access point must be changed from either Monitor Mode 
or Local Mode of operation to Spectrum Connect Mode.
Step 1:
 Log into the Wireless LAN Controller
Step 2:
 Navigate to WIRELESS.
Step 3:
Select the closest CleanAir AP to the suspected issue.
Step 4:
 From the drop-down list next to AP Mode, change to SE-Connect.
23