Applying Power and Verifying the Installation
Verifying the Installation ▀
ASR 5000 Installation Guide ▄
179
Figure 57. Card-Level Status LEDs for the Channelized Line Card
Channelized Line Card Run/Fail LED States
The Run/Fail LED on the Channelized line card indicates the overall status of the card. These LEDs are illuminated
steady green during normal operation.
steady green during normal operation.
If the LED is not green, use the troubleshooting information in the table to diagnose the problem.
Table 73.
Channelized Line Card Run/Fail LED States
Color
Description
Troubleshooting
Green Card powered with no errors detected None needed.
Red
Card powered with error(s) detected
Errors were detected during the POSTs. It is likely that the errors were
logged to the system's command line interface during the boot process.
logged to the system's command line interface during the boot process.
None
Card is not receiving power
Verify that the power source is supplying ample voltage and current to the
chassis.
chassis.
Verify that the card is properly installed per the instructions in this
document.
document.
If all of the above suggestions have been verified, it is possible that the
line card is not functional. Please contact your service representative.
line card is not functional. Please contact your service representative.