Cisco Cisco Packet Data Interworking Function (PDIF) Guía De Instalación
![Cisco](https://files.manualsbrain.com/attachments/7380d0050044647c30f5c24bbbf5d0c0b6d9bb84/common/fit/150/50/faa183d287233c52228cfea3dbc2a127fe780f60564fcb0955d9c3d1cd23/brand_logo.png)
Application Card Installation
▀ Chassis Slot Numbering and Assignments
▄ ASR 5000 Installation Guide
86
Recommended Minimum Chassis Configuration
The recommended minimum chassis configuration for application cards, including redundancy, is as follows:
Slot Number
Card
Card State
8
SMC
Active
9
SMC
Standby
2 and 4 (see Note 1)
2, 3 and 4 (see Note 2)
2, 3 and 4 (see Note 2)
PSC2 or PSC3 Active
11 (see Notes 1 and 2)
PSC2 or PSC3 Standby
Notes:
1. Minimum requirement for hardware redundancy.
2. Minimum requirement for hardware + software redundancy, MME service, SGSN service, as well as combined
services on a single platform.
services on a single platform.
Install additional cards in the remaining chassis slots as required.
If you use the session recovery feature, a minimum of three active packet processing cards and one standby (redundant)
packet processing card are required.
packet processing card are required.