Cisco Cisco Packet Data Interworking Function (PDIF) Guía Para Resolver Problemas
Global Configuration Mode Commands
▀ threshold edr-udr-dropped flow control
▄ Cisco ASR 5000 Series Command Line Interface Reference
OL-22948-01
threshold edr-udr-dropped flow control
This command configures thresholds to monitor the total number of EDRs and UDRs discarded due to flow control.
Product
All
Privilege
Security Administrator, Administrator
Syntax
Configures the default setting.
Default: High threshold: 90; Low threshold: 10
Default: High threshold: 90; Low threshold: 10
Default: 90
The high threshold for total number of EDRs + UDRs dropped due to flow control, which must be met or
exceeded within the polling interval to generate an alert or alarm.
The high threshold for total number of EDRs + UDRs dropped due to flow control, which must be met or
exceeded within the polling interval to generate an alert or alarm.
must be an integer from 0 through 100000.
A value of 0 indicates the threshold.
Default: 10
The low threshold for total number of EDRs + UDRs dropped that maintains a previously generated alarm
condition. If the total number of EDRs + UDRs dropped falls below the low threshold within the polling
interval, a clear alarm is generated.
The low threshold for total number of EDRs + UDRs dropped that maintains a previously generated alarm
condition. If the total number of EDRs + UDRs dropped falls below the low threshold within the polling
interval, a clear alarm is generated.
must be an integer from 0 through 100000, and must be lower than
.
A value of 0 disables the threshold.
Usage
Use this command to configure thresholds to monitor the total number of EDRs + UDRs discarded due to
flow control. Alerts or alarms are generated based on the total number of EDRs + UDRs dropped during
polling interval.
Alerts or alarms are triggered for EDR file space usage session based on the following rules:
flow control. Alerts or alarms are generated based on the total number of EDRs + UDRs dropped during
polling interval.
Alerts or alarms are triggered for EDR file space usage session based on the following rules:
Enter condition: Actual number of EDRs + UDRs dropped >= specified number of EDRs + UDRs
dropped.
Clear condition: Actual number of EDR + UDRs dropped < specified clear number of EDRs + UDRs
dropped.
If a trigger condition exists at the end of the polling interval, the alert or alarm will not be generated until the
end of the polling interval.
Refer to the
end of the polling interval.
Refer to the
command to configure the polling interval and the
command to enable thresholding for this value.