Cisco Cisco Packet Data Interworking Function (PDIF) Guía Para Resolver Problemas
PDSN Service Configuration Mode Commands
▀ threshold a11-rrp-failure
▄ Cisco ASR 5000 Series Command Line Interface Reference
OL-22948-01
threshold a11-rrp-failure
Set an alarm or alert based on the number of A11 Registration Response failures for the PDSN service.
Product
PDSN
Privilege
Security Administrator, Administrator
Syntax
Deletes the alert or alarm.
Default: 0
The high threshold number of A11 Registration Response failures that must be met or exceeded within the
polling interval to generate an alert or alarm. It can be configured to any integer value between 0 and 100000.
The high threshold number of A11 Registration Response failures that must be met or exceeded within the
polling interval to generate an alert or alarm. It can be configured to any integer value between 0 and 100000.
Default:0
The low threshold number of A11 Registration Response failures that must be met or exceeded within the
polling interval to clear an alert or alarm. It can be configured to any integer value between 0 and 100000.
The low threshold number of A11 Registration Response failures that must be met or exceeded within the
polling interval to clear an alert or alarm. It can be configured to any integer value between 0 and 100000.
Important:
This value is ignored for the Alert model. In addition, if this value is not configured for the Alarm
model, the system assumes it is identical to the high threshold.
Usage
Use this command to set an alert or an alarm when the number of A11 Registration Response failures is equal
to or greater than a specified number.
Alerts or alarms are triggered for the number of A11 Registration Response failures based on the following
rules:
to or greater than a specified number.
Alerts or alarms are triggered for the number of A11 Registration Response failures based on the following
rules:
Enter condition: Actual number of A11 Registration Response failures > High Threshold
Clear condition: Actual number of A11 Registration Response failures £ Low Threshold
Example
The following command configures a number of A11 Registration Response failures threshold of
The following command configures a number of A11 Registration Response failures threshold of
and a low
threshold of
for a system using the Alarm thresholding model: