Global Configuration Mode Commands   
▀  threshold poll dcca-unknown-rating-group 
 
▄  Cisco ASR 5000 Series Command Line Interface Reference 
OL-22947-02   
threshold poll dcca-unknown-rating-group 
This command configures the polling interval for DCCA Unknown Rating Group threshold. 
Product
 
ECS 
Privilege
 
Security Administrator, Administrator 
Syntax
 
Configures the default setting. 
Defaut: 900 seconds 
Specifies the polling interval for DCCA Unknown Rating Group threshold, in seconds. 
 must be an integer value from 60 through 60000. 
Usage
 
This command configures the polling interval for DCCA Unknown Rating Group threshold. 
Important:
  All configured polling intervals are rounded up to the closest multiple of 30. For example, if a 
polling interval is configured for 130 seconds, the system uses a polling interval of 150 seconds. 
Refer to the 
 and other threshold commands for additional information on the 
system‘s support for thresholding in this chapter. 
Example 
The following command configures the polling interval to 600 seconds to threshold for the unknown DCCA Rating 
Group (content-id) returned by Diameter to system: