Cisco Cisco Packet Data Interworking Function (PDIF) Guía Para Resolver Problemas
Channelized Port Configuration Mode Commands
threshold rx-utilization ▀
Cisco ASR 5000 Series Command Line Interface Reference ▄
OL-22947-02
threshold rx-utilization
Configures thresholds for receive-port utilization.
Product
SGSN
Privilege
Security Administrator, Administrator
Syntax
Default: 80
The high threshold receive port utilization percentage that must be met or exceeded within the polling interval
to generate an alert or alarm.
The percentage can be configured to any integer value between 0 and 100.
The high threshold receive port utilization percentage that must be met or exceeded within the polling interval
to generate an alert or alarm.
The percentage can be configured to any integer value between 0 and 100.
Default: 80
Allows the configuration of the low threshold.
The low threshold receive port utilization percentage that maintains a previously generated alarm condition.
If the utilization percentage falls below the low threshold within the polling interval, a clear alarm will be
generated.
The percentage can be configured to any integer value between 0 and 100.
Allows the configuration of the low threshold.
The low threshold receive port utilization percentage that maintains a previously generated alarm condition.
If the utilization percentage falls below the low threshold within the polling interval, a clear alarm will be
generated.
The percentage can be configured to any integer value between 0 and 100.
Important:
This value is ignored for the Alert model. In addition, if this value is not configured for the Alarm
model, the system assumes it is identical to the high threshold.
Usage
Receive port utilization thresholds generate alerts or alarms based on the utilization percentage of each
configured port in relation to data received during the specified polling interval. This threshold is configured
on a per-port basis.
configured port in relation to data received during the specified polling interval. This threshold is configured
on a per-port basis.
Important:
Ports configured for half-duplex do not differentiate between data received and data transmitted.
Therefore, to avoid redundant alarms, it is recommended that only the receive or transmit utilization threshold be
configured.
configured.
Alerts or alarms are triggered for receive port utilization based on the following rules:
Enter condition: Actual percent utilization of a port for received data ³ High Threshold
Clear condition: Actual percent utilization of a port for received data < Low Threshold
If a trigger condition occurs within the polling interval, the alert or alarm will not be generated until the end
of the polling interval.
of the polling interval.