Global Configuration Mode Commands
threshold dcca-protocol-error ▀
Cisco ASR 5000 Series Command Line Interface Reference ▄
OL-22947-02
threshold dcca-protocol-error
Configures the threshold for Diameter Credit Control Application (DCCA) protocol error from Diameter server.
Product
ECS
Privilege
Security Administrator, Administrator
Syntax
Disables the threshold for configured alarm and sets the
and
values to 0.
Default: 0
The high threshold number of protocol error received from Diameter server that must be met or exceeded
within the polling interval to generate an alert or alarm.
The number can be configured to any integer value between 0 and 1044000.
The high threshold number of protocol error received from Diameter server that must be met or exceeded
within the polling interval to generate an alert or alarm.
The number can be configured to any integer value between 0 and 1044000.
Default: 0
The low threshold number of protocol error received from Diameter server that maintains a previously
generated alarm condition. If the number of errors falls beneath the low threshold within the polling interval,
a clear alarm will be generated.
The number can be configured to any integer value between 0 and 1044000.
The low threshold number of protocol error received from Diameter server that maintains a previously
generated alarm condition. If the number of errors falls beneath the low threshold within the polling interval,
a clear alarm will be generated.
The number can be configured to any integer value between 0 and 1044000.
Important:
This value is ignored for the Alert model. In addition, if this value is not configured for the Alarm
model, the system assumes it is identical to the high threshold.
Usage
In the event that the system receives the protocol errors from Diameter server, dcca-protocol-error is
generated.
DCCA protocol error threshold generates alerts or alarms based on the number of protocol error messages
received from Diameter server during the specified polling interval.
Alerts or alarms are triggered for DCCA protocol error based on the following rules:
generated.
DCCA protocol error threshold generates alerts or alarms based on the number of protocol error messages
received from Diameter server during the specified polling interval.
Alerts or alarms are triggered for DCCA protocol error based on the following rules:
Enter condition: Actual number of DCCA protocol error ³ High Threshold
Clear condition: Actual number of DCCA protocol errors < Low Threshold
If a trigger condition occurs within the polling interval, the alert or alarm will not be generated until the end
of the polling interval.
of the polling interval.
Example