Cisco Cisco Packet Data Interworking Function (PDIF) Guía Para Resolver Problemas
Global Configuration Mode Commands
threshold mme-auth-failure ▀
Cisco ASR 5000 Series Command Line Interface Reference ▄
OL-22947-02
threshold mme-auth-failure
Use this command to configure thresholds for the total number of MME Auth Failure messages to count across all the
MME services in the system as threshold limit to generate alert or alarm.
MME services in the system as threshold limit to generate alert or alarm.
Product
MME
Privilege
Security Administrator, Administrator
Syntax
Default: 0 (Disabled)
The high threshold number of total MME Auth Failure messages across all MMM services on a system that
must be met or exceeded within the polling interval to generate an alert or alarm.
The number can be configured to any integer value from 0 through 100000. A value of 0 disables the
threshold.
The high threshold number of total MME Auth Failure messages across all MMM services on a system that
must be met or exceeded within the polling interval to generate an alert or alarm.
The number can be configured to any integer value from 0 through 100000. A value of 0 disables the
threshold.
Default: 0 (Disabled)
The low threshold number of total MME Auth Failure messages across all services on a system that maintains
a previously generated alarm condition. If the number of MME Attach Failure messages, across all the
services in a system, falls beneath the low threshold within the polling interval, a clear alarm will be
generated.
The number can be configured to any integer value between 0 and 100000. A value of 0 disables the
threshold.
The low threshold number of total MME Auth Failure messages across all services on a system that maintains
a previously generated alarm condition. If the number of MME Attach Failure messages, across all the
services in a system, falls beneath the low threshold within the polling interval, a clear alarm will be
generated.
The number can be configured to any integer value between 0 and 100000. A value of 0 disables the
threshold.
Important:
This value is ignored for the Alert model. In addition, if this value is not configured for the Alarm
model, the system assumes it is identical to the high threshold.
Usage
Use this command to monitor and set alarms or alerts when the total number of MME Auth Failure message
across all the MME services in the system is equal to or greater than the set limit.
Alerts or alarms are triggered for the total number of MME Auth Failure message based on the following
rules:
across all the MME services in the system is equal to or greater than the set limit.
Alerts or alarms are triggered for the total number of MME Auth Failure message based on the following
rules:
Enter condition: Actual total number of MME Auth Failure messages ³ High Threshold
Clear condition: Actual total number of MME Auth Failure messages < Low Threshold
If a trigger condition occurs within the polling interval, the alert or alarm will not be generated until the end
of the polling interval.
Refer to the
of the polling interval.
Refer to the
command to configure the polling interval and the
command to enable thresholding for this value.