Cisco Cisco Packet Data Interworking Function (PDIF) Manual De Mantenimiento
G-CDR and Enhanced G-CDR Field Reference Tables
▀ CDR Fields Supported in eG-CDRs
▄ Cisco ASR 5000 Series AAA Interface Administration and Reference
OL-23000-01
List of Service Data Volumes
List of Service Data Volumes
Rating group
M This is the service flow identity and has to be used for differentiated evaluation of user‘s traffic. Also
known as content-id.
Charging Rulebase
name
name
M The name of the Rulebase used for charging This is the group name of charging rules.
Result Code
O The result code AVP This contains the result code after the interconnection with the CRF.
Local Sequence
number
number
M A per service data container sequence number. It starts from 1 for each service, increasing by 1 for
each service date container generated for that service within the lifetime of this PDP session.
Time of first usage
M The time stamp for the first IP packet to be transmitted for the service data flow referred to the
current instance of Service Condition Change.
Time of last usage
M The time stamp for the last IP packet to be transmitted for the service data flow referred to the current
instance of Service Condition Change.
Usage time
M The difference between ―time of first usage‖ and ―time of last usage‖.
Service condition
change
change
M The reason for closing the service data container for triggers like SGSN change, QoS change, RAT
change, time and volume triggers, etc.
QoS negotiated
O The negotiated QoS applied for the service data flow.
sgsn-Address
M The valid SGSN IP address during the service data recording interval.
SGSN PLMN
identifier
identifier
O The valid SGSN PLMN ID during the service data recording interval.
FBC Data volume
uplink
uplink
M The number of octets transmitted during the use of the packet data services in the uplink direction.
FBC data volume
downlink
downlink
M The number of octets transmitted during the use of the packet data services in the downlink direction.
Time of report
M A time stamp defining the moment when the service data container is closed.
RAT Type
O The valid RAT type during the service data recording interval.
Failurehandling
Continue
Continue
O A Boolean expression included if the failure handling condition has been executed.
Service Identifier
O The service identifier may designate an end user service, a part of an end user service or an arbitrarily
formed group thereof.
Notes:
LOSDV related changes:
Time Quota mechanism: Contains two further subfields and is included if envelope reporting is required:
Time Quota Type identifies the mechanism by which time-based usage should be reported — as defined
in TS 32.299.
Base Time Interval identifies the length of the base time interval, for controlling the reporting of time-
based usage, in seconds.
User location information will be included in the LOSDV container in the R7 eG-CDRs.