  Engineering Rules 
Service Rules  ▀   
Cisco ASR 5000 Series Packet Data Serving Node Administration Guide  ▄  
 
  OL-22939-01 
Service Rules 
The following engineering rules apply to services configured within the system: 
 
 
A maximum of 256 services (regardless of type) can be configured per system. 
Caution:
  Large numbers of services greatly increase the complexity of management and 
may impact overall system performance (i.e. resulting from such things as system handoffs). 
Therefore, it is recommended that a large number of services only be configured if your application 
absolutely requires it. Please contact your local service representative for more information. 
 
Up to 2,048 Security Parameter Indices (SPIs) can be configured for a single PDSN service. 
 
Up to 2,048 MN-HA and 2048 FA-HA SPIs can be supported for a single HA service. 
 
Up to 2,048 FA-HA SPIs can be supported for a single FA service. 
 
The system supports unlimited peer FA addresses per HA. 
 
The system maintains statistics for a maximum of 8192 peer FAs per HA service. 
 
If more than 8192 FAs are attached, older statistics are identified and overwritten. 
 
The system maintains statistics for a maximum of 4096 peer HAs per FA service. 
 
There are a maximum of 8 HA assignment tables per context and per chassis. 
 
The total number of entries per table and per chassis is limited to 256.  
 
Up to 10,000 LAC addresses can be configured per LNS service. 
 
 
 
Even though service names can be identical to those configured in different contexts on the same system, this is 
not a good practice. Having services with the same name can lead to confusion, difficulty troubleshooting 
problems, and make it difficulty understanding outputs of show commands.