  Installation Notes
ARP Table Is Corrupted When Multiple BVIs Are Configured
The bridge supports only one bridge virtual interface (BVI). Multiple BVIs should not be configured 
because the ARP table can be corrupted.
Bridge Power Up LED Colors 
During power up, the bridge LEDs display the following color sequences:
1.
The Install LED is initially turned off.
2.
The Install LED turns amber.
3.
The Status LED turns amber during the boot loader process.
4.
The Ethernet, Status, and Radio LEDs turn green during the loading of the operating system.
5.
The Ethernet, Status, and Radio LEDs turn amber during the loop-back test.
6.
The Status LED starts to blink green, and then the Ethernet LED starts to blink green.
7.
The Ethernet, Status, and Radio LEDs blink amber twice to show that the auto-install process has 
started.
8.
During the auto-install process, the Ethernet, Status, and Radio LEDs turn off for a short time 
period, and then go through a blinking sequence twice. Each LED sequentially blinks at the 
following rates before becoming continuously amber: 
a.
Slow blinking rate of 1 blink per second.
b.
Medium blinking rate of 2 blinks per second.
c.
Fast blinking rate of 4 blinks per second.
9.
The Install LED starts to blink amber to show that the bridge is searching for a root bridge.
10.
When the bridge associates to a root bridge, the Install LED turns amber.
11.
When the bridge becomes a root bridge and is waiting for a nonroot bridge to associate, the Install 
LED blinks green.
12.
When the root bridge has a nonroot bridge associated, the Install LED turns green.
Bridge Cannot Detect Simultaneous Image Downloads
Do not attempt to load software images into the bridge from both a Telnet session and a console session 
simultaneously. The bridge cannot detect that two images are being loaded at the same time. For best 
results, use the archive download command in the CLI.
Bridge Cannot Detect Invalid Software When Using copy Command 
The bridge sometimes cannot detect invalid software images when you load software using the copy 
command. For best results, use the archive download command in the CLI to load new software.
Telnet Session Sometimes Hangs or Will Not Start During Heavy Traffic
When the bridge is transmitting and receiving heavy traffic, you sometimes cannot start a Telnet session 
and some existing Telnet sessions halt. However, this behavior is expected because the bridge gives top 
priority to data traffic and a lower priority to Telnet traffic.