Cisco Cisco Aironet 350 Workgroup Bridges Notas de publicación

Descargar
Página de 12
 
5
Installation Notes
OL-2384-01
Installation Notes
Use the Authenticator Configuration page in access point firmware version 11.06 to select the draft of 
the 802.1x protocol the access point radio should use. Follow these steps to set the draft for your access 
point:
Step 1
Browse to the Authenticator Configuration page in the access point management system.
a.
On the Summary Status page, click Setup.
b.
On the Setup page, click Security.
c.
On the Security Setup page, click Authentication Server.
Step 2
Use the 802.1x Protocol Version (for EAP authentication) pull-down menu to select the draft of the 
802.1x protocol the access point radio should use. Menu options include:
Draft 7—No radio firmware versions compliant with Draft 7 have LEAP capability, so you 
should not need to select this setting.
Draft 8—Select this option if LEAP-enabled client devices that associate with this access point 
use radio firmware versions 4.13, 4.16, or 4.23, or if workgroup bridges associating with this 
access point use firmware version 8.58_2 or earlier.
Draft 10—This is the default setting in access point and bridge firmware versions 11.06 and 
later. Select this option if client devices that associate with this access point or bridge use 
Microsoft Windows XP EAP authentication, if LEAP-enabled client devices that associate with 
this bridge use radio firmware version 4.25 or later, or if workgroup bridges associating with 
this access point use firmware version 8.65_2 or later.
Step 3
Click Apply or OK to apply the setting. The access point reboots.
Installation Notes
Verify Mounting Hole Measurement
If you make a photocopy of the mounting template (included in Mounting Instructions for the Cisco 
Aironet Access Points, Base Stations, and Workgroup Bridges with Plastic Cases), 
make sure that the 
distance between the holes is 4 3/4 in. (12.06 cm) before you drill the holes. Some photocopy machines 
do not make exact duplicates of the original.
AP34x/35x 11.06 and later
1
x
x
AP34x/35x 11.07 and later
x
x
AP34x/35x and BR35x 11.08T
x
x
1.
The default draft setting in access point firmware version 11.06 and later is 
Draft 10.
Table 2
802.1x Protocol Drafts and Compliant Client Firmware (continued)
Firmware Version
Draft 7
Draft 8
Draft 10