Cisco Cisco Packet Data Interworking Function (PDIF) Guía De Administador
Troubleshooting
▀ Detecting Faulty Hardware
▄ Cisco ASR 5000 System Administration Guide
194
Detecting Faulty Hardware
When power is applied to the chassis, power is sequentially applied to management cards, application cards and line
cards.
cards.
Each PFU, application and line card installed in the system incorporates light emitting diodes (LEDs) that indicate its
operating status. This section describes how to use these status LEDs to verify that all of the installed components are
functioning properly.
operating status. This section describes how to use these status LEDs to verify that all of the installed components are
functioning properly.
Important:
As the system progresses through its boot process, some cards will not exhibit immediate LED
activity. Allow several minutes to elapse after a reboot is initiates before checking the LEDs on the various cards to
verify that the boot process has successfully completed.
verify that the boot process has successfully completed.
Using the CLI to View Status LEDs
The status of application and line card LEDs can be viewed through the CLI by entering the show leds all command in
Exec mode.
Exec mode.
The following displays a sample of this command’s output.
Slot 01: Run/Fail: Green | Active: Off | Standby: Green
Slot 08: Run/Fail: Green | Active: Green | Standby: Off
Status: Green | Service: Off |
Slot 09: Run/Fail: Green | Active: Off | Standby: Green
Status: Green | Service: Off |
Slot 12: Run/Fail: Green | Active: Green | Standby: Off
Slot 14: Run/Fail: Green | Active: Green | Standby: Off
Slot 17: Run/Fail: Green | Active: Green | Standby: Off
Slot 24: Run/Fail: Green | Active: Green | Standby: Off
Slot 25: Run/Fail: Green | Active: Off | Standby: Green
Slot 30: Run/Fail: Green | Active: Green | Standby: Off
Slot 33: Run/Fail: Green | Active: Off | Standby: Off
Slot 40: Run/Fail: Green | Active: Green | Standby: Off
Slot 08: Run/Fail: Green | Active: Green | Standby: Off
Status: Green | Service: Off |
Slot 09: Run/Fail: Green | Active: Off | Standby: Green
Status: Green | Service: Off |
Slot 12: Run/Fail: Green | Active: Green | Standby: Off
Slot 14: Run/Fail: Green | Active: Green | Standby: Off
Slot 17: Run/Fail: Green | Active: Green | Standby: Off
Slot 24: Run/Fail: Green | Active: Green | Standby: Off
Slot 25: Run/Fail: Green | Active: Off | Standby: Green
Slot 30: Run/Fail: Green | Active: Green | Standby: Off
Slot 33: Run/Fail: Green | Active: Off | Standby: Off
Slot 40: Run/Fail: Green | Active: Green | Standby: Off
The status of the two Power Filter Units (PFUs) can be viewed by entering the show power chassis command in the
Exec mode.
Exec mode.