Getting Started   
▀  Using the ASR 5500 Quick Setup Wizard 
 
 
▄  ASR 5500 System Administration Guide, StarOS Release 18 
40 
   
Table 2.  Quick Setup Wizard Logic Diagram Callout Descriptions 
Item
 
Task
 
Description/Notes
 
Enter or exit the wizard. 
Enter no at the prompt to automatically be directed to the command line 
interface (CLI). Proceed to 
 for 
instructions on performing an initial system configuration with the CLI. 
Enter setup at the command prompt to re-invoke the wizard. 
For release 19.2 and higher, configure a 
tech-support password. 
The tech-support password is used to access cli test-commands. 
Configure an administrative 
username/password and a hostname for the 
system. 
The name of the default administrative user configured through the wizard 
is admin.  
Administrative user name is an alphanumeric string of 1 through 32 
characters that is case sensitive. 
Administrative user password is an alphanumeric string of 1 through 63 
characters that is case sensitive. 
Configure a valid, non-null hostname. The hostname is an alphanumeric 
string of 1 through 63 characters that is case sensitive. 
Change chassis key value. 
A unique chassis key is configured at the factory for each system. This 
key is used to decrypt encrypted passwords found in generated 
configuration files. The system administrator can create a unique chassis 
key that will be used to encrypt passwords stored in configuration files. 
Enter yes to set a new chassis key. Refer to the instructions in System 
Settings
. Additional information can be found in the System Security 
chapter. 
Configure a single Management 
Input/Output (MIO/UMIO) out-of-band 
management interface for out-of-band 
system management. 
Traffic on the management LAN is not transferred over the same media as 
user data and control signaling. 
For security reasons, it is recommended that management functions be 
maintained on a separate network from user data and control signaling. 
MIO port 1 (mio1) is the 1000Base-T default management port. 
MIO port 2 (mio2) is available as a secondary management port. 
Use the RJ-45 interfaces to connect the system to the management 
network with CAT5 Ethernet cable. 
Configure an IP address, subnet mask, and gateway for the interface. 
Instructions for configuring the second management interface on the MIO 
can be found in the System Settings chapter. 
Enable various remote access protocols for 
accessing the system. 
Secure Shell (SSH) uses TCP port number 22 by default, if enabled. 
SSH V1 and/or V2 are supported. 
If SSH is enabled, you can also enable SSH File Transfer Protocol (SFTP) 
server functionality. 
Note: For maximum security, use only SSH v2.