Cisco Cisco Packet Data Interworking Function (PDIF)
egcdr time-duration algorithm
This command allows you to specify the algorithm to compute the duration of time utilization in an eG-CDR
for the current rulebase.
for the current rulebase.
Product
GGSN
Privilege
Security Administrator, Administrator
Command Modes
Exec > ACS Configuration > Rulebase Configuration
active-charging service service_name > rulebase rulebase_name
Entering the above command sequence results in the following prompt:
[local]
host_name
(config-rule-base)#
Syntax Description
egcdr time-duration algorithm { consumed-time consumed_time [ plus-idle ] | continuous-time-periods
ctp_time | parking-meter seconds }
{ default | no } egcdr time-duration algorithm
no
If previously configured, deletes the eG-CDR time-duration algorithm configuration from the current rulebase.
default
Configures this command with its default setting.
Default: Algorithm configured for CCA, or the CCA default if none is configured.
consumed-time consumed_time [ plus-idle ]
Specifies the actual consumption time in seconds. This is used to determine the actual used chargeable time
envelopes for the purpose of consuming time quota.
envelopes for the purpose of consuming time quota.
consumed_time must be an integer from 1 through 4294967295.
Default: 0 (disabled)
Time envelope is the basis for reporting active usage. For each time envelope, the time consumption includes
the time duration between arrival of last packet and first packet only.
the time duration between arrival of last packet and first packet only.
plus-idle: Specifies the idle time between arrival of two packets to include in time usage record in eG-CDR.
When used along with consumed-time it indicates the active usage + idle time, when no traffic flow occurs.
Command Line Interface Reference, Modes A - B, StarOS Release 19
643
ACS Rulebase Configuration Mode Commands
egcdr time-duration algorithm