This value is ignored for the Alert model. In addition, if this value is not configured for the Alarm model,
the system assumes it is identical to the high threshold.
Important
Usage Guidelines
In the event that the system receives the protocol errors from Diameter server, dcca-protocol-error is generated.
DCCA protocol error threshold generates alerts or alarms based on the number of protocol error messages
received from Diameter server during the specified polling interval.
Alerts or alarms are triggered for DCCA protocol error based on the following rules:
• Enter condition: Actual number of DCCA protocol error is greater than or equal to the high threshold.
• Clear condition: Actual number of DCCA protocol errors is less than the low threshold.
If a trigger condition occurs within the polling interval, the alert or alarm will not be generated until the end
of the polling interval.
Examples
The following command configures a high threshold count of 250 protocol errors and low threshold of 100
for a system using the Alarm thresholding model:
threshold dcca-protocol-error 250 clear 100
   Command Line Interface Reference, Modes G - H, StarOS Release 19
500
Global Configuration Mode Commands (T-threshold phspc)
threshold dcca-protocol-error