Cisco Cisco ASR 5000
Credit Control Configuration Mode Commands
▀ associate
▄ Command Line Interface Reference, StarOS Release 18
2816
associate
This command associates/disassociates a failure handling template with the Diameter Credit Control Application
(DCCA) service.
(DCCA) service.
Product
GGSN
HA
HSGW
IPSG
PDSN
P-GW
S-GW
SAEGW
Privilege
Security Administrator, Administrator
Mode
Exec > ACS Configuration > Credit Control Configuration
active-charging service service_name > credit-control
Entering the above command sequence results in the following prompt:
[local]host_name(config-dcca)#
Syntax
associate failure-handling-template template_name
no associate failure-handling-template
no
Disassociates a failure handling template with the DCCA service.
failure-handling-template template_name
Associates a previously created failure handling template with the DCCA service.
template_name
specifies
the name for a pre-configured failure handling template.
template_name
must be an alphanumeric string of
1 through 63 characters.
For more information on failure handling templates, refer to the
For more information on failure handling templates, refer to the
failure-handling-template
command
in the Global Configuration Mode Commands chapter.
Usage
Use this command to associate a configured failure handling template with the DCCA service.
The failure handling template defines the action to be taken when the Diameter application encounters a
failure supposing a result-code failure, Tx-expiry or response-timeout. The application will take the action
given by the template. For more information on failure handling template configurations, refer to the
Diameter Failure Handling Template Configuration Mode Commands chapter.
The failure handling template defines the action to be taken when the Diameter application encounters a
failure supposing a result-code failure, Tx-expiry or response-timeout. The application will take the action
given by the template. For more information on failure handling template configurations, refer to the
Diameter Failure Handling Template Configuration Mode Commands chapter.