Cisco Cisco Packet Data Gateway (PDG)
Global Configuration Mode Commands (threshold ppp - url-blacklisting)
threshold total-hnbgw-ue-sessions ▀
Command Line Interface Reference, StarOS Release 18 ▄
5981
threshold total-hnbgw-ue-sessions
Configures alarm or alert thresholds for the total number of UEs connected to an HNB-GW service across all the HNB-
GW services in the system.
GW services in the system.
Product
HNB-GW
Privilege
Security Administrator, Administrator
Mode
Exec > Global Configuration
configure
Entering the above command sequence results in the following prompt:
[local]host_name(config)#
Syntax
threshold total-hnbgw-ue-sessions high_thresh [ clear low_thresh ]
high_thresh
Default: 0 (Disabled)
Specifies the high threshold for the total number of UEs connected across all HNB-GW services on a system
that must be met or exceeded within the polling interval to generate an alert or alarm.
Specifies the high threshold for the total number of UEs connected across all HNB-GW services on a system
that must be met or exceeded within the polling interval to generate an alert or alarm.
high_thresh
is an integer from 0 through 4000000. A value of 0 disables the threshold.
clear
low_thresh
Default: 0 (Disabled)
Specifies the low threshold for the total number of UEs connected to HNB-GW service across all HNB-GW
services that maintains a previously generated alarm condition. If the number of UE sessions across all the
services in a system, falls beneath the low threshold within the polling interval, a clear alarm will be
generated.
Specifies the low threshold for the total number of UEs connected to HNB-GW service across all HNB-GW
services that maintains a previously generated alarm condition. If the number of UE sessions across all the
services in a system, falls beneath the low threshold within the polling interval, a clear alarm will be
generated.
low_thresh
is an integer from 0 and 4000000. A value of 0 disables the threshold.
Important:
This value is ignored for the Alert model. In addition, if this value is not configured for the Alarm
model, the system assumes it is identical to the high threshold.
Usage
Use this command to monitor and set alarms or alerts when the total number of UEs connected to HNB-GW
service across all HNB-GW services in the system is equal to or greater than the set limit.
Alerts or alarms are triggered for the total number of UEs connected across all HNB-GW service on a system
based on the following rules:
service across all HNB-GW services in the system is equal to or greater than the set limit.
Alerts or alarms are triggered for the total number of UEs connected across all HNB-GW service on a system
based on the following rules:
Enter condition: Actual total number of UEs connected to HNB-GW service across all HNB-GW
services on a system is greater than the high threshold.
Clear condition: Actual total number of UEs connected to HNB-GW service across all HNB-GW
services on a system is less than the low threshold.