Cisco Cisco Packet Data Interworking Function (PDIF)
Global Configuration Mode Commands (T-threshold phspc)
threshold call-setup ▀
Command Line Interface Reference, StarOS Release 18 ▄
5631
threshold call-setup
Configures call setup, alarm or alert thresholds for the system.
Product
All
Privilege
Security Administrator, Administrator
Mode
Exec > Global Configuration
configure
Entering the above command sequence results in the following prompt:
[local]host_name(config)#
Syntax
threshold call-setup high_thresh [ clear low_thresh ]
high_thresh
Default: 0
Specifies the high threshold number of calls setup by the system that must be met or exceeded within the
polling interval to generate an alert or alarm.
Specifies the high threshold number of calls setup by the system that must be met or exceeded within the
polling interval to generate an alert or alarm.
high_thresh
is an integer from 0 through 100000. A value of 0 disables the threshold.
clear
low_thresh
Default: 0
Specifies the low threshold number of calls setup by the system that maintains a previously generated alarm
condition. If the number of setups falls beneath the low threshold within the polling interval, a clear alarm
will be generated.
Specifies the low threshold number of calls setup by the system that maintains a previously generated alarm
condition. If the number of setups falls beneath the low threshold within the polling interval, a clear alarm
will be generated.
low_thresh
is an integer from 0 through 100000. A value of 0 disables the threshold.
Important:
This value is ignored for the Alert model. In addition, if this value is not configured for the Alarm
model, the system assumes it is identical to the high threshold.
Usage
Call setup thresholds generate alerts or alarms based on the total number of calls setup by the system during
the specified polling interval.
Alerts or alarms are triggered for call setups based on the following rules:
the specified polling interval.
Alerts or alarms are triggered for call setups based on the following rules:
Enter condition: Actual number of call setups is greater than or equal to the high threshold.
Clear condition: Actual number of call setups is less than the low threshold.
If a trigger condition occurs within the polling interval, the alert or alarm will not be generated until the end
of the polling interval.
Refer to the
of the polling interval.
Refer to the
threshold poll
command to configure the polling interval and the
threshold monitoring
command to enable thresholding for this value.
Example