Cisco Cisco Packet Data Interworking Function (PDIF)
Global Configuration Mode Commands (T-threshold phspc)
▀ threshold mme-attach-failure
▄ Command Line Interface Reference, StarOS Release 18
5698
threshold mme-attach-failure
Configures alarm or alert thresholds for the total number of MME Attach Failure messages across all the MME services
in the system.
in the system.
Product
MME
Privilege
Security Administrator, Administrator
Mode
Exec > Global Configuration
configure
Entering the above command sequence results in the following prompt:
[local]host_name(config)#
Syntax
threshold total-mme-attach-failure high_thresh [ clear low_thresh ]
high_thresh
Default: 0 (Disabled)
Specifies the high threshold number of total MME Attach Failure messages across all services on a system
that must be met or exceeded within the polling interval to generate an alert or alarm.
Specifies the high threshold number of total MME Attach Failure messages across all services on a system
that must be met or exceeded within the polling interval to generate an alert or alarm.
high_thresh
can be configured to an integer from 0 through 100000. A value of 0 disables the threshold.
clear
low_thresh
Default: 0 (Disabled)
Specifies the low threshold number of total MME Attach Failure messages across all services on a system
that maintains a previously generated alarm condition. If the number of MME Attach Failure messages across
all the services in a system, falls beneath the low threshold within the polling interval, a clear alarm will be
generated.
Specifies the low threshold number of total MME Attach Failure messages across all services on a system
that maintains a previously generated alarm condition. If the number of MME Attach Failure messages across
all the services in a system, falls beneath the low threshold within the polling interval, a clear alarm will be
generated.
low_thresh
is an integer from 0 through 100000. A value of 0 disables the threshold.
Important:
This value is ignored for the Alert model. In addition, if this value is not configured for the Alarm
model, the system assumes it is identical to the high threshold.
Usage
Use this command to monitor and set alarms or alerts when the total number of MME Attach Failure message
across all the MME services in the system is equal to or greater than the set limit.
Alerts or alarms are triggered for the total number of MME Attach Failure message based on the following
rules:
across all the MME services in the system is equal to or greater than the set limit.
Alerts or alarms are triggered for the total number of MME Attach Failure message based on the following
rules:
Enter condition: Actual total number of MME Attach Failure messages is greater than or equal to the
high threshold.
Clear condition: Actual total number of MME Attach Failure messages is less than the low threshold